Scroll down to start reading the guide
Follow this guide to readjust your American base installation to a metric ISO system with a Swedish base instead.
NOTE! Make sure IRONCAD is closed before doing this!
Start by downloading and extracting this file which contains all metrically adapted templates:
Copy the extracted folder \Template.
Go to this path:
C:\Users\*YOUR USER*\AppData\Roaming\IronCAD\IRONCAD\26.0\en-us
You can also use this "quick access" path to the folder: %appdata%\IronCAD\IRONCAD\26.0\en-us
Right-click the existing \Template folder and select Delete.
Paste the new \Template folder instead.
Download and extract our customized sheet metal tables with Swedish designations from this link:
Download sheet metal tables for v2024
Copy both sheet metal tables Stocktbl.txt and Tooltbl.txt.
Go to this folder:
C:\Users\*YOUR USER*\AppData\Local\IronCAD\IRONCAD\26.0\en-us\SheetMetal
You can also use this "quick access" path to the folder: %localappdata%\IronCAD\IRONCAD\26.0\en-us\SheetMetal
Delete the two existing files and paste the new files there (or simply replace them).
You can also navigate to the program's installation path and paste and replace the two files there using:
C:\Program Files\IronCAD\2024\AppData\en-us\SheetMetal
This ensures the sheet metal tables are immediately correct for any new user on the same computer.
If you get an error message after the installation process is complete, it may be due to a space in your Windows username. Try unpacking the installation file manually by following the steps below. We have provided instructions for both Windows 11 and Windows 10.
This applies to Windows 11
If the path to the folder handling "Documents" and "Downloads" etc. contains a space in your username (\FirstName_space_LastName\), you need to manually unpack the installation file; otherwise, an error message will appear during installation. To unpack, you can use WinRAR/WinZIP, for example, or preferably the user-friendly and compact 7-Zip: https://www.7-zip.org/
You can then right-click the downloaded file and select Show more options

Then select 7-Zip followed by Extract to "IronCAD_DCS2023SP1_SWE\

Then run the installation file in the new folder by right-clicking the *.exe file and selecting Run as administrator:

This applies to Windows 10
If the path to the folder managing "My Documents" and "Downloaded Files", etc., contains a space in your username (\Firstname_space_Lastname\), you need to extract the installation file manually; otherwise, an error message will appear during installation. To extract it, you can use, for example, WinRAR/WinZIP or preferably the user-friendly and compact 7-zip: https://www.7-zip.org/
You can then right-click the downloaded file and choose to extract it to a new folder, which will be created automatically.

Then run the installation file itself in the new folder by right-clicking the *.exe file and selecting Run as administrator:

Download and extract our customized catalogs from this link:
Copy all contents of the \Drawing folder
Paste and replace the catalogs at this path: C:\Program Files\IronCAD\2024\AppData\en-us\Catalogs\Drawing
Then do the same with the contents of the \Scene folder (copy all contents)
Paste and replace the catalogs at this path: C:\Program Files\IronCAD\2024\AppData\en-us\Catalogs\Scene
Download and extract this file, which contains two registry files:
Download registry files for v2024
This is what happens when the registry entries are installed.
*CUS = Current User Settings -> it applies to the currently logged-in user via \\CURRENT USER and overrides existing registry settings, but does not remove any (e.g., if more files were opened than specified in CUS, etc.).
*NUS = New User Settings -> it modifies the default settings under \\LOCAL MACHINE used by CUS when a new Windows user runs ironcad for the first time.
Double-click each registry file one by one to install it (repeat the same process below for both files).
A warning message will appear, looking like the image below.

Click Yes on this prompt followed by OK.

When installing the US base version of IronCAD DCS 2024, an American version of the IronCAD mechanical add-on (also known as ICM) is also included. It is not possible to install a localized version of ICM (US) over another localized version (Swe). Therefore, you need to uninstall the existing version to replace it with another one.
Go to Control Panel > Add or Remove Programs and uninstall the existing (US) installation of IronCAD mechanical.
Download and install our Swedish edition of the IC mechanical add-on: