Scroll down to start reading the guide
Follow this guide to readjust your American base installation to a metric ISO system with a Swedish base instead.
NOTE! Make sure IRONCAD is closed before doing this!
Start by downloading and unzipping this ZIP file containing all the metrically adapted templates:
Copy the extracted folder \Template.
Go to this path:
C:\Users\*YOUR USER*\AppData\Roaming\IronCAD\IRONCAD\28.0\en-us
You can also use this general "quick access" to the folder: %appdata%\IronCAD\IRONCAD\28.0\en-us
Right-click the existing \Template folder and select Delete.
Paste the new \Template folder instead.
Download and extract our customized sheet metal tables with Swedish designations from this link:
Download sheet metal tables for v2026
Copy both sheet metal tables Stocktbl.txt and Tooltbl.txt.
Go to this folder:
C:\Users\*YOUR USER*\AppData\Local\IronCAD\IRONCAD\28.0\en-us\SheetMetal
You can also use this general "quick access" to the folder: %localappdata%\IronCAD\IRONCAD\28.0\en-us\SheetMetal
Delete the two existing files and paste the new files there (or simply replace them).
You can also navigate to the program's installation path and paste and replace the two files there using:
C:\Program Files\IronCAD\2026\AppData\en-us\SheetMetal
This ensures the sheet metal tables are immediately correct for any new user on the same computer.
If you get an error message after the installation process is complete, it may be due to a space in your Windows username. Try unpacking the installation file manually by following the steps below. We have provided instructions for both Windows 11 and Windows 10.
This applies to Windows 11
If the path to the folder handling "Documents" and "Downloads" etc. contains a space in your username (\FirstName_space_LastName\), you need to manually unpack the installation file; otherwise, an error message will appear during installation. To unpack, you can use WinRAR/WinZIP, for example, or preferably the user-friendly and compact 7-Zip: https://www.7-zip.org/
You can then right-click the downloaded file and select Show more options

Then select 7-Zip followed by Extract to "IronCAD_DCS2023SP1_SWE\

Then run the installation file in the new folder by right-clicking the *.exe file and selecting Run as administrator:

This applies to Windows 10
If the path to the folder managing "My Documents" and "Downloaded Files", etc., contains a space in your username (\Firstname_space_Lastname\), you need to extract the installation file manually; otherwise, an error message will appear during installation. To extract it, you can use, for example, WinRAR/WinZIP or preferably the user-friendly and compact 7-zip: https://www.7-zip.org/
You can then right-click the downloaded file and choose to extract it to a new folder, which will be created automatically.

Then run the installation file itself in the new folder by right-clicking the *.exe file and selecting Run as administrator:

Download and extract our customized catalogs from this link:
Copy all contents of the \Drawing folder
Paste and replace the catalogs in this path: C:\Program Files\IronCAD\2026\AppData\en-us\Catalogs\Drawing
Then do the same with the contents of the \Scene folder (copy all contents)
Paste and replace the catalogs in this path: C:\Program Files\IronCAD\2026\AppData\en-us\Catalogs\Scene
Download and unzip this ZIP file, which contains a number of registry files:
Download registry files for v2026
The REG files for IRONCAD are named 2026SP1-IC_CUS.reg and 2026SP1-IC_NUS.reg.
The REG files for INOVATE are named 2026SP1-IV_CUS.reg and 2026SP1-IV_NUS.reg.
The REG files for IRONCAD DRAFT are named 2026SP1-ID_CUS.reg and 2026SP1-ID_NUS.reg.
The REG files for IRONCAD COMPOSE are named 2026SP1-CM_CUS.reg and 2026SP1-CM_NUS.reg.
These registry files change, among other things, the Options settings to our recommended settings and take effect the next time the program is started.
Read more about our recommended settings here.
*CUS = Current User Settings -> applies to the currently logged-in user via \\CURRENT USER and replaces existing registry settings, but does not delete any existing settings (e.g., if you have opened more files than what is set in "CUS" etc.).
*NUS = New User Settings -> changes the default settings under \\LOCAL MACHINE, which are then copied to "CUS" when a new Windows user runs IC for the first time.
Double-click each registry file one by one to install it (repeat the same process below for both files).
A warning message will appear, looking like the image below.

Click Yes on this prompt followed by OK.

When installing the US basic version of IronCAD 2026, an American version of the add-on IronCAD Mechanical (also known as ICM). It is not possible to install one "region-specific version" of IC Mech over another version. For example, the US version cannot be installed over the Swedish version, and vice versa.
Therefore, you must first uninstall an existing version in order to replace it with another.
Go to Control Panel > Add or Remove Programs and uninstall the existing (US) installation of IronCAD mechanical.
Download and install our Swedish version of the IC Mechanical add-on: