Menu
1. Drawing templates for v20272. Sheet metal tables for v20273. Catalogs for v20274. Recommended settings for v20275. IC Mechanical v2027
Solidmakarnas Logotype

Metric conversion of the U.S. IRONCAD(v2027)

Scroll down to start reading the guide

1. Drawing templates for v2027

‍

Follow this guide to readjust your American base installation to a metric ISO system with a Swedish base instead.

NOTE! Make sure IRONCAD is closed before doing this!

‍

Start by downloading and unzipping this ZIP file containing all the metrically adapted templates:

Download Templates for v2027 (updated September 1, 2026)

‍

Copy the extracted folder \Template.

Go to this path:

C:\Users\*YOUR USER*\AppData\Roaming\IronCAD\IRONCAD\29.0\en-us

You can also use this general "shortcut" to the folder: %appdata%\IronCAD\IRONCAD\29.0\en-us

‍

Right-click the existing \Template folder and select Delete.

Paste the new \Template folder instead.

2. Sheet metal tables for v2027

‍

Download and extract our customized sheet metal tables with Swedish designations from this link:

Download sheet metal tables for v2027 (updated September 1, 2026)

‍

Copy both sheet metal tables Stocktbl.txt and Tooltbl.txt.

Go to this folder:

C:\Users\*YOUR USER*\AppData\Local\IronCAD\IRONCAD\29.0\en-us\SheetMetal

You can also use this general "shortcut" to the folder: %localappdata%\IronCAD\IRONCAD\29.0\en-us\SheetMetal

Delete the two existing files and paste the new files there (or simply replace them).

‍

You can also navigate to the program's installation path and paste and replace the two files there using:

C:\Program Files\IronCAD\2027\AppData\en-us\SheetMetal

This ensures the sheet metal tables are immediately correct for any new user on the same computer.

3. Catalogs for v2027

‍

Download and extract our customized catalogs from this link:

Download catalogs for v2027 (updated September 1, 2026)

‍

Copy all contents of the \Drawing folder

Paste and replace the catalogs in this path: C:\Program Files\IronCAD\2027\AppData\en-us\Catalogs\Drawing‍

‍

Then do the same with the contents of the \Scene folder (copy all contents)

Paste and replace the catalogs in this path: C:\Program Files\IronCAD\2027\AppData\en-us\Catalogs\Scene

4. Recommended settings for v2027

‍

Download and unzip this ZIP file, which contains a number of registry files:

Download registry files for v2027 (updated September 1, 2026)

‍

The REG files for IRONCAD are named 2027SP1-IC_CUS.reg and 2027SP1-IC_NUS.reg.

The REG files for INOVATE are named 2027SP1-IV_CUS.reg and 2027SP1-IV_NUS.reg.

The REG files for IRONCAD DRAFT are named 2027SP1-ID_CUS.reg and 2027SP1-ID_NUS.reg.

The REG files for IRONCAD COMPOSE are named 2027SP1-CM_CUS.reg and 2027SP1-CM_NUS.reg.

‍

These registry files change, among other things, the Options settings to our recommended settings and take effect the next time the program is started.

Read more about our recommended settings here.

‍

*CUS = Current User Settings -> applies to the currently logged-in user via \\CURRENT USER and replaces existing registry settings, but does not delete any existing settings (e.g., if you have opened more files than what is set in "CUS" etc.).

*NUS = New User Settings -> changes the default settings under \\LOCAL MACHINE , which are then copied to "CUS" when a new Windows user runs IC for the first time.

‍

Approach

Double-click each registry file one by one to install it (repeat the same process below for both files).

A warning message will appear, looking like the image below.

‍

Click Yes on this prompt followed by OK.

5. IC Mechanical v2027

‍

When installing the US base version of IronCAD 2027, a US version of the add-on is also included IronCAD Mechanical (also known as IC Mech or ICM). It is not possible to install a different version of IC Mech over a "region-specific version" of IC Mech. For example, the US version cannot be installed over the Swedish version, and vice versa.

If you have installed the U.S. version, or if you're not sure, first uninstall the existing version to replace it with the Swedish version, which you'll find below.

‍

Go to Control Panel > Add or Remove Programs and uninstall the existing (US) installation of IronCAD mechanical.

Download and install our Swedish version (always the latest) of the IC Mechanical 2027 add-on:

Download ICMechanical Swe v2027