Service Pack 1 for IronCAD DCS 2022 PU1

LAST CHECKED:

October 29, 2026

Service Pack 1 for IronCAD DCS 2022 PU1
Emil Rindell

Emil Rindell

Jonas Bryntesson

Jonas Bryntesson

Henrik Andersson

Henrik Andersson

PUBLISHED:

2022-07-18

Emil Rindell

Emil Rindell

Jonas Bryntesson

Jonas Bryntesson

Henrik Andersson

Henrik Andersson

2022-07-18

Read the entire post for proper installation instructions

Service Pack 1 for IronCAD DCS 2022 PU1 (2022.01.01.0) has now been released. Please read this entire post for a proper installation.

  • Service Pack 1 can only be installed if you already have version 2022 with PU1 previously installed.
  • Service Pack 1 updates all software included in the Design Collaboration Suite (IRONCAD, INOVATE, DRAFT, and COMPOSE)
  • Service Pack 1 cannot be uninstalled separately. To uninstall, the entire IronCAD DCS 2022 must be uninstalled.
  • Files created in SP1 can be opened with software without SP1

‍

The difference between a PU (Product Update) and an SP (Service Pack) is that a PU contains both new features and quality improvements, whereas an SP contains only quality improvements.

‍

Download Service Pack 1 for IronCAD DCS 2022 PU1 here

See what has been fixed in Service Pack 1

‍

How do I know which version I have?

Go to Menu, Help, About and verify that you see the text "Version 24.0 Product Update 1".

‍

As mentioned above, Product Update 1 is required to install this Service Pack. By checking under Help, About, you can see whether Product Update 1 is installed. If you are missing Product Update 1, you can first download it here.

‍

Important information regarding the installation of SP1 for v2022 PU1

It is important that you uncheck the installation of IC Mechanical when adding SP1. If this is not done, the US distribution will overwrite the Swedish distribution of IC Mechanical and your open catalogs may be closed. If this has already happened on your computer, scroll down the post to see how you can resolve this.

‍

Deselect IC Mechanical according to the image before installation, then click Install to begin the installation.

‍

‍

‍

Fixing an American installation of IC Mechanical

If you have accidentally installed the American edition of IC Mechanical, you first need to download the Swedish edition. You can do this via this link:

https://www.solidmakarna.se/nedladdningscenter?program=IC+Mechanical&version=2022

‍

Then go to Windows Control Panel > Uninstall a program

Next, scroll down the list and select IronCAD Mechanical.
Then click Uninstall and follow the on-screen uninstallation wizard

‍

Then start the installation of the Swedish edition of IC Mechanical that you just downloaded. Read these instructions for the correct installation of IC Mechanical:

https://www.solidmakarna.se/installation-och-aktivering/mechanical-installation

‍

If your previous catalogs have "disappeared", you will need to open them manually.
You do this via Catalogs>Open and then select the catalogs you want to open followed by Open.

‍


To easily manage which catalogs should be open, to easily switch between different default "catalog sets" and to quickly fix if catalogs are undesirably shut down in the future, you can use PROCatalogSet. There you can build your own library of catalogs. Please read this post for more information:

https://www.solidmakarna.se/supportblogg/procatalogset-hantera-dina-kataloger

‍

‍